To determine which component is preventing your dryer from heating, we recommend a sequential test of the burner assembly. Before starting, ensure you have unplugged the dryer and turned off the gas supply for your safety.

  1. Inspect the Igniter:

Locate the igniter near the gas valve. If the igniter is functioning correctly, it should glow yellow when the dryer is running. If it does not glow at all, or if you see visible hairline cracks or dark spots, the igniter is likely faulty. You can verify this by using a multimeter to test for continuity; a reading of infinity indicates the igniter is “open” and must be replaced.

  1. Test the Gas Valve Solenoids:

If the igniter glows but the gas does not ignite, the issue is typically the two-coil gas valve solenoids. These coils control the gas flow to the burner. To test them, disconnect the wire harness from the solenoid pack and use a multimeter in the lowest ohms mode. A finite resistance reading means the coil is healthy, while an open circuit reading confirms the solenoid has failed.

Because gas and electrical diagnostics involve safety risks, You Can Count on Us to provide professional assistance if you are uncomfortable performing these tests. We offer Same-day or next-day appointments across the Seattle metro area with Certified Technicians to ensure your dryer is repaired safely and efficiently.

Estimates are subject to on-site diagnostic and parts availability. Results may vary based on appliance condition. Contact a certified technician for safety-sensitive repairs (gas/electrical).